IME designs and manufactures in Italy measuring instruments and integrated systems. The application fields are: electric measurement, industrial automation, energy management and protection. IME was founded in 1946 and it started producing analogue instruments for the measurement of a.c. and d.c. electrical quantities. Today IME designs and produces analogue and digital measuring instruments and integrated systems for various application fields in Italy: electrical measurement, industrial automation, energy management, and protection.

Digital Meters
Electrical quantities measurement in low voltage application
Active energy Three-phase network, unbalanced load, 3 or 4 wire (selectable) Connection with external dedicated CT 4 Module

Model: MF6FT000xx
Input : 1A …..5A
Auxiliary : 115…..230Vac

Electrical quantities measurement (4 quadrants)
Active and reactive energy (2 quadrants) Three-phase network, unbalance load, 3 or 4 wire (selectable) Pulse output for remote active energy monitoring RS485 communication

 Model: MF4AT400xx
Input : 1A …..5A
Auxiliary : 115…..230Vac

Electrical quantities measurement in low voltage application
Active and reactive energy Three-phase network, unbalanced load, 3 or 4 wire Connection with dedicated CT CT selection 5...8000A (38 ranges) Pulse output for remote energy monitoring RS232 or RS485 communication 6 Module

 Model: MF1CTx00xx
Input : 5A
Auxiliary : 115…..240Vac

Electrical quantities measurement in low voltage application
Active energy Three-phase network, unbalanced load, 3 or 4 wire Connection with CT CT ratio selection 5...8000A (38 ranges) Pulse output for remote energy monitorin

 Model:MF2BT000xx
Input : 5A
Auxiliary : 115…..240Vac
Analogue Meters
Accuracy: cl. 1,5
Voltage drop: from 700mV (50µA)
Nominal temperature range: 0...40°C
Accuracy: cl. 1,5
Current consumption: approx 10mA
Nominal temperature range: 0...40°C
DIRECT CURRENT DIGITAL METER
 Auxiliary: 24Vac -240Vac
Input: 1…20mA
48x48 flush mounting
DIRECT VOLTAGE DIGITAL METER
 
Transducer
CURRENT TRANSDUCER
To measure average value, calibration according r.m.s. value Supply taken from measurement (selfsupplied)...(2Module)
Input: 1A-6A
Output: 0……5ma
VOLTAGE TRANSDUCER
To measure average value, calibration according r.m.s. Supply taken from measurement (selfsupplied)
Input: 100V-440V
Output: 0V..10V
LOW-VOLTAGE MEASURING TRANSFORMER
Passing bus bar primary Single-phase current transformer Primary current 200…6000A Secondary current 1A - 5A
LOW-VOLTAGE MEASURING TRANSFORMER
Single-Phase Transformer
Wound primary Single-phase current transformer Primary current 5…100A Secondary current 1A - 5A
LOW VOLTAGE TRANSFORMERS
Current transformers Normal secondary current 5A or 1A Frequency 47÷63Hz Insulation reference voltage 0,72kV test voltage 3kV for 1’ at 50Hz